LYNCS
Modular manual ultrasonic scanners provide encoded probe positioning for corrosion mapping and weld, flange and nozzle inspection across application-specific configurations.

Product overview
This family of manual and semi-automated ultrasonic scanners provides application-specific platforms for corrosion mapping and weld integrity assessment. Modular frames, probe holders and positioning systems support PAUT, TFM and TOFD inspection workflows, with configurations for small-bore tubing, carbon steel, non-ferrous components, hot assets, flanges and nozzles.
The scanners guide ultrasonic probes across the inspection surface while encoders supply position feedback to the inspection instrument. Depending on the configuration, magnetic wheels secure the scanner to ferrous surfaces, adjustable chains accommodate ferrous or non-ferrous components, or an XY frame tracks both scan and index movement for corrosion mapping. The XY solution supports localized immersion using an Aquablock waterbox, linear arrays with a 0L wedge and dual linear arrays.
Application-specific designs address different access and operating requirements. The small-bore scanner requires 11mm (0.43in) radial clearance for the scanner alone, excluding transducers and wedges, while the high-temperature configuration supports online weld inspection at temperatures up to 350°C (662°F). Flange scanning from the tapered neck is described as providing complete sealing-face coverage, and the nozzle configuration adds encoded skew and probe-position feedback.
Entry-level versions offer encoded PA or TOFD probe positioning on ferrous piping and vessels, with modular conversion to a non-ferrous chain scanner. A separate compact encoder scanner uses a universal clamp to hold probe and wedge combinations and permits one-handed operation in restricted spaces.
Key capabilities
Application-specific modularity
Scanner configurations address corrosion mapping, welds, flanges and nozzles with adjustable frames and probe holders.
Low-profile small-bore scanning
Snap-together links adapt the small-bore scanner to different pipe diameters with single- or dual-probe configurations.
Encoded XY mapping
The lightweight fixed-frame corrosion scanner includes scan-axis and index-axis encoders for accurate XY positioning.
Longitudinal and circumferential scanning
The carbon steel long-seam system converts between axial and circumferential weld inspection.
Non-ferrous chain attachment
Quick-link chains support encoded probe movement on ferrous and non-ferrous pipes, vessels and tanks.
High-temperature inspection
The dedicated magnetic scanner supports on-stream weld inspection up to 350°C (662°F) with heat-resistant cable management and an oversized encoder wheel.
Flange-face assessment
An articulating magnetic frame guides one or two phased array probes around flange couplings.
Encoded nozzle positioning
The nozzle scanner combines skew encoding, Y-axis feedback and leadscrew probe positioning.
Entry-level flexibility
The entry-level weld scanner includes PA and TOFD holding arms and can be converted into a non-ferrous chain scanner.
Universal clamp option
A compact encoder scanner holds a range of probe and wedge combinations for one-handed use in confined spaces.
Published technical specifications
Values as published by Eddyfi Technologies. Where models or variants differ, each is listed separately.
Boiler Tube and Small Diameter Pipe Weld Inspection
- Pipe Diameter Range
- 21.4mm - 114.3mm (0.84in - 4.5in)
- Minimum Radial Clearance — specification table; scanner only
- 1 mm (0.433 in)
- Encoder
- RS422 line driver, compatible with all standard encoder inputs
- Encoder Resolution
- 31.30 counts/mm (795.0 counts/in)
- Probe Holding Capacity — specification table
- 1 phased array wedges
- Encoder Cable Length
- 3 m (9.8 ft)
- Inspection Surface
- Ferrous and non-ferrous
- Radial Scanner Clearance
- 11mm (0.43in)
- Scanner Height
- 11mm (0.43in)
- Scanner Width
- 53.5mm (2.1in)
- Scanner Depth — excludes cable management sleeving
- 105.6mm (4.2in)
- Scanner Weight
- 0.09kg (0.2lb)
- Shipping Weight — approximate standard kit
- 3.1kg (6.8lb))
- Operating Environment
- -20°C (-4°F) to 50°C (122°F)
- Environmental Sealing
- Watertight (submersible)
- Encoder cable guard removal threshold
- 31.75mm (1.25in)
- Probe configurations — feature description
- Single or Dual Probe Configuration
Carbon Steel XY Corrosion Mapping
- Frame bar with ruler
- 750mm (29.5in)
- Position encoding
- Dual encoder - scan and index axis
- Linear array wedge
- 0L wedge
Carbon Steel Weld Inspection — Circumferential Scanning
- Probe capacity — description
- up to four Phased Array (PA) and/or TOFD probes
- Fabrication and in-service circumferential weld range
- 100mm (4in) to flat plate
- High-temperature version — description
- up to 350°C (660°F)
Carbon Steel Weld Inspection — Long Seam Scanning
- Scanner capacity — description
- four-probe longitudinal weld seam scanner
- Axial scanning probe configuration — key features
- two probes
- Minimum axial pipe size — key features
- 15.24cm (6in)
Carbon Steel Weld Inspection
- Pipe Range, Circumferential
- 25.4cm (10in) to flat
- Pipe Range, Longitudinal
- 15.2cm (6in) to flat
- Circumferential range with slip-joint probe holders
- 10.2 cm (4 in) - 25.4 cm (10 in)
- Encoder Resolution
- 9.05 counts/mm (230.0 counts/in)
- Probe Holding Capacity — specification table
- 2 phased array wedges
- Encoder Cable Length
- 5m (16.4ft)
- Inspection Surface
- Ferrous materials
- Long Seam Clearance
- 14cm (5.5in)
- Circumferential Clearance
- 8.9cm (3.5in)
- Frame Height
- 10.5cm (4.1in)
- Frame Height (Pivot)
- 19cm (4.5in)
- Frame Width
- 45.4cm (17.9in)
- Frame Depth
- 17.5cm (6.9in)
- Frame Width (Pivot)
- 35cm (13.8in)
- Frame Weight
- 1.9kg (4.25lb)
- Operating Environment
- -20°C (-4°F) to 50°C (122°F)
- Environmental Sealing
- Watertight (submersible)
- Phased Array Probe Holder — Minimum Wedge Width
- 17.1mm (0.7in)
- Phased Array Probe Holder — Maximum Wedge Width
- 57.6mm (2.3in)
- TOFD Probe Holder — Minimum Wedge Width
- 17.1mm (0.7in)
- TOFD Probe Holder — Maximum Wedge Width
- 45mm (1.8in)
Non-Ferrous Weld Inspection
- Single-probe scanning width
- 10cm (3.94in)
- Dual-probe scanning width
- 25cm (9.84in)
- Diameter range — description
- 10.2 to 96.5cm (4 to 38in)
- Diameter range — adjustable chain key feature
- 10.7 to 96.5cm (4.2 to 38in)
- Pipe Range, Circumferential — specification table
- 12.4 - 96.5cm (4.9 - 38in)
- Encoder Resolution
- 9.05 counts/mm (230.0 counts/in)
- Probe Holding Capacity
- 2 Phased Array Probes
- Encoder Cable Length
- 5m (16.4ft)
- Inspection Surface
- Ferrous or non-ferrous materials
- Radial Scanner Clearance
- 10.7cm (4.2in)
- Frame Height
- 10.5cm (4.1in)
- Frame Width
- 43.5cm (17.1in)
- Frame Depth
- 17.5cm (6.9in)
- Frame Weight
- 1.4kg (3.1lb)
- Operating Environment
- -20°C (-4°F) to 50°C (122°F)
- Environmental Sealing
- Watertight (submersible)
- Minimum Wedge Width
- 17mm (0.67in)
- Maximum Wedge Width
- 55.8mm (2.2in)
High Temperature Weld Inspection
- Encoded probe configuration — description
- two probes
- Pipe Range, Circumferential
- 10.2cm (4in) to flat
- Pipe Range, Internal
- Flat to 152.4cm (60in)
- Encoder Resolution
- 4.28 counts/mm (108.7 counts/in)
- Probe Holding Capacity
- 2 or 4 wedges
- Encoder Cable Length
- 5m (16.4ft)
- Inspection Surface
- Ferrous materials
- Radial Clearance
- 8.9cm (3.5in)
- Frame Height
- 10.5cm (4.1in)
- Frame Width
- 17.5cm (6.9in)
- Frame Length
- 45.4cm (17.9in)
- Frame Weight
- 1.3kg (2.8lb)
- Operating Environment
- -20°C (-4°F) to 350°C (662°F)
- Environmental Sealing
- Watertight (submersible)
- Phased Array Probe Holder — Minimum Wedge Width
- 17mm (0.67in)
- Phased Array Probe Holder — Maximum Wedge Width
- 55.8mm (2.2in)
- TOFD Probe Holder — Minimum Wedge Width
- 17mm (0.67in)
- TOFD Probe Holder — Maximum Wedge Width
- 44.4mm (1.75in)
Flange Face Corrosion Inspection
- Probe configuration
- one or two phased array probes
- Minimum diameter
- 7.6cm (3in)
- Sealing-face coverage when scanning from tapered neck
- 100%
Nozzle Inspection
- Supported instruments
- two-axis and three-axis instruments
- Nozzle angle — description
- 90-degree
- Minimum nozzle size — description
- 76.2mm (3in)
- Clearance — description
- 127mm (5in)
- Encoded skew probe holder vertical travel
- 12.2cm (4.8in)
- Pipe Range — specification table
- 10.2cm - 60cm (4in - 24in)
- Encoder Resolution
- 16.3 counts/mm (414.5 counts/inch)
- Y-Axis Encoder Resolution
- 161.3 counts/mm (4096.0 counts/inch)
- Skew Axis Encoder Resolution
- 2.84 counts/deg.
- Probe Holding Capacity
- 1 wedge
- Encoder Cable Length
- 5m (16.4ft)
- Inspection Surface
- Non-ferrous or ferrous materials
- Radial Clearance — with standard frame bar
- 31.9cm (12.6in)
- Standard frame bar
- 30 cm (11.8 in)
- Vertical Clearance
- 12.5cm (4.9in)
- Low Profile Link Height
- 6.1cm (2.4in)
- Low Profile Link Width
- 8cm (3.2in)
- Low Profile Link Depth
- 25cm (9.8in)
- Low Profile Link Weight
- 0.55kg (1.12lb)
- Encoded Skew Vertical Probe Holder Height
- 32.2cm (12.7in)
- Encoded Skew Vertical Probe Holder Width
- 11.6cm (4.6in)
- Encoded Skew Vertical Probe Holder Depth
- 14.2cm (5.6in)
- Encoded Skew Vertical Probe Holder Weight
- 0.75kg (1.7lb)
- Operating Environment
- -20°C (-4°F) to 50°C (122°F)
- Environmental Sealing
- Dust-tight, watertight (not submersible)
- Minimum Wedge Width
- 36mm (1.4in)
- Maximum Wedge Width
- 44mm (1.7in)
Entry Level Inspections
- Probe capacity
- two TOFD or PA probes
- Carbon steel long-seam scanner: standard tool post arms supplied for wedge widths from 17.1mm (0.7in) to 57.6mm (2.3in).
- Nozzle scanner: standard 30 cm (11.8 in) frame bar.
- Entry-level weld scanner: TOFD and phased array probe-holding arms for the slip joint probe holder.
- Entry-level weld scanner: integrated positional encoder, magnetic wheels, brake, cable clips and ergonomic handle.
- Entry-level universal-clamp scanner: encoder and universal clamp system.
- Small-bore scanner: custom umbilical lengths.
- Carbon steel, non-ferrous, high-temperature and nozzle scanners: custom encoder cable lengths.
- Carbon steel long-seam scanner: alternative tool post arms.
- Carbon steel long-seam scanner: optional slip-joint probe holders, sold separately.
- Carbon steel circumferential scanner: high-temperature version up to 350°C (660°F).
- High-temperature scanner: optional alternate probe holder arms.
- High-temperature scanner: ergonomic handle.
- Nozzle scanner: alternate probe holders with additional vertical clearance.
- Nozzle scanner: cable management sleeving, sold separately.
- Entry-level weld scanner: additional magnetic wheels, probe holders and alternate frame bars.
- Entry-level weld scanner: conversion to a non-ferrous chain scanner.
- A15 probes
- Eddyfi Technologies phased array instruments
- Aquablock waterbox
- Aqualock V2
- Linear array probes with 0L wedge
- Dual linear array probes
- Phased array probes
- TOFD probes
- Gekko instruments
- Small-bore scanning below 31.75mm (1.25in) requires removal of the encoder cable guard.
- Small-bore radial clearance applies to the scanner only, excluding transducers and wedges; the specification table states 1 mm (0.433 in), while the features and radial scanner clearance state 11mm (0.43in).
- Small-bore scanner depth excludes cable management sleeving; shipping weight is approximate for standard kit contents.
- Small-bore, carbon steel, non-ferrous and nozzle scanner operating environments are -20°C (-4°F) to 50°C (122°F).
- Carbon steel and high-temperature magnetic scanner specifications require ferrous materials; flange magnetic wheels adhere to ferrous surfaces and the entry-level weld scanner is intended for ferrous surfaces.
- Carbon steel circumferential scanning below 25.4cm (10in), down to 10.2cm (4in), requires optional slip-joint probe holders.
- The non-ferrous scanner diameter ranges differ between the description, key features and specification table; these values are retained separately.
- Some probe-holder arm styles may provide additional maximum wedge width for carbon steel, non-ferrous and high-temperature scanners.
- High-temperature scanner operating environment is -20°C (-4°F) to 350°C (662°F).
- Flange sealing-face coverage of 100% is stated for scanning from the tapered neck.
- Nozzle description and specification table state different minimum sizes and clearance values; these values are retained separately.
- Nozzle radial clearance is specified with the standard 30 cm (11.8 in) frame bar.
- Nozzle environmental sealing is dust-tight and watertight, but not submersible.
- Technical specifications are subject to change.
Compatibility lists only items named by Eddyfi for this product; confirm configuration with EMUS before ordering.
Typical applications
- Corrosion mapping on vessels and pipework
- High Temperature Hydrogen Attack detection
- Boiler tube and small-diameter pipe weld inspection
- Austenitic stainless steel weld inspection
- Carbon steel plate and pipe weld inspection
- Wet hydrogen sulfide damage assessment
- Train axle inspection
- Corrosion under pipe supports
- Non-ferrous weld inspection
- High-temperature on-stream weld inspection
- Flange-face corrosion inspection
- Nozzle weld inspection
- Pressure vessel circumferential weld inspection
- Pipe-to-elbow and feature weld inspection
- Storage tank and silo weld inspection
- Longitudinal seam and ERW inspection
- Crack detection, sizing and monitoring
- Corrosion and erosion detection and sizing
- Rope-access inspections
Official brochures
Corrosion Mapping Applications Brochure
High Temperature Hydrogen Attack (HTHA) Applications Brochure
Advanced Weld Inspection for Austenitic Steel Applications Brochure
Advanced Weld Inspection for Carbon Steel Applications Brochure
Wet Hydrogen Sulfide Damage Applications Brochure
Train Axle Inspection Applications Brochure
Learn more
Carbon Steel Weld Plates & Pipes Applications Brochure
Austenitic Stainless Steel Applications Brochure
Corrosion Mapping Applications Brochure
Additional documents
Other Eddyfi products
How EMUS supports this
Equipment is only part of the answer. Every system we supply is backed by regional engineering, service and application support.
Mechanical, electrical, environmental setup done right the first time.
Qualification and acceptance testing against real criteria.
Operator and application training built around your parts.
Traceable calibration to keep measurements audit-ready.
Preventive and corrective service across the Balkan region.
Method development and problem-solving with our engineers.
Eddyfi Technologies
Part of the Eddyfi Technologies portfolio, represented by EMUS across the Balkan region.
Application Notes & resources
Official application notes and technical literature for LYNCS.
Request an Engineering Consultation
Talk to an EMUS engineer about this product and whether it fits your inspection workflow.