Battery-powered, remotely controlled scanners automate PAUT and conventional UT corrosion mapping and multi-technique weld inspection on ferrous and non-ferrous assets.

PAUTTFMConventional UTTOFD
AUT Scanners product image
Overview

Product overview

This scanner family combines battery-powered motion control with ultrasonic inspection equipment for remote corrosion mapping, single-line surveys and weld examination. Magnetic crawlers serve ferrous assets, including inverted surfaces, while chain-driven configurations support ferrous and non-ferrous pipes. Interchangeable attachments allow the systems to be configured for different inspection tasks.

For phased array corrosion mapping, the Aqualock waterbox couples a 7.5MHz 64-element probe through a controlled water column rather than a wedge. Its bubble-removal flow design and foam seal liner support consistent coupling on challenging surfaces. The page specifies 1mm (0.04in) mapping resolution and recordable, auditable data sets. Conventional UT configurations instead use a focused single-crystal probe with local immersion coupling in a gimbaled holder, with twin-crystal options also available.

Weld inspection configurations deploy PAUT and TOFD probes, with integrated instrument capabilities supporting simultaneous TFM, PAUT and TOFD acquisition. Ferrous crawlers accommodate up to six PAUT or TOFD probes, while the non-ferrous chain-link system carries up to four. Applications include circumferential, longitudinal and spiral welds on pipes, vessels, tanks and other structures.

The scanners integrate with Gekko, Mantis and TOPAZ instruments for acquisition, analysis and reporting. Typical work includes corrosion and erosion assessment, hydrogen-related damage detection and inspection of steel, composite and plastic assets. Conventional ultrasonic corrosion mapping can operate at surface temperatures up to 150°C / 302°F; the ferrous crawler requires its medium-temperature add-on kit between 50°C (122°F) and 150°C (302°F).

Key Features

Key capabilities

Remote battery operation

Portable, battery-operated systems provide fully automated, remotely controlled scanning.

Magnetic and chain-driven configurations

Magnetic crawlers support ferrous surfaces, while chain-driven configurations work on ferrous and non-ferrous pipes.

Aqualock coupling

Water-column coupling, bubble-removal flow and a foam seal liner support phased array mapping on challenging surfaces.

Conventional UT mapping

A focused single-crystal probe in a gimbaled holder supports local immersion mapping without requiring phased array-qualified personnel.

Multi-technique weld acquisition

Simultaneous TFM, PAUT and TOFD multi-probe, multigroup configurations collect weld data in a single file.

Corrosion analysis tools

Floating and tracking gates, assisted analysis, wall-loss statistics and report-building tools support corrosion assessment.

Adaptable scanning attachments

Interchangeable bridges, raster arms and probe holders adapt the system to different access and coverage requirements.

Single-line scanning

Probe holders can mount directly to the crawler body for one-axis UT or PAUT corrosion surveys.

Remote inspection accessories

Optical guides, HD cameras and actuated tool posts support alignment, navigation and probe transport.

Specifications

Published technical specifications

Values as published by Eddyfi Technologies. Where models or variants differ, each is listed separately.

Benefits at a glance

Asset diameter range
70mm (2.75in) diameter pipes to flat plates
Scan speed
up to 250mm/sec (9.84in/sec)
Index speed
up to 762mm/sec (0-30in/sec)

Phased Array Corrosion Mapping

Resolution
1mm (0.04in)
Scan area and time
1m (3.28ft) x 0.6m (1.96ft) in 90 seconds
Probe
7.5MHz 64-element probe

Magnetic corrosion mapping configuration

Asset range
76.2mm (3in) OD to flat plate

Non-Magnetic corrosion mapping configuration

Diameter range
15.24 and 106.7cm (6 and 42in)

Non-Intrusive Inspection

Claimed cost savings versus Internal Visual Inspection
up to a 9:1 cost savings

Ultrasonic Corrosion Mapping

Operating surface temperature capability
up to 150°C / 302°F
Umbilical length options
up to 60m
Interchangeable bridge range
300mm (12in) to 1160mm (46in)
Limited-access bridge
300mm (11.8in)
Larger-surface bridge
600mm (23.6in) and above

PAUT & TOFD Weld Inspection

Standard tool post arm minimum wedge width
17.1mm (0.7in)
Standard tool post arm maximum wedge width
57.6mm (2.3in)
Calibration
3-click calibration wizards
PWI speed relative to FMC-based TFM
typically 4x faster

Ferrous weld inspection

Simultaneous probe capacity
up to six PAUT or TOFD probes

Non-Ferrous weld inspection

Probe capacity per scan
up to four PAUT or TOFD probes

FERROUS INSPECTION SOLUTION

Crawler Weight
7.7kg (17lb)
Crawler Height
12.5cm (4.9in)
Crawler Height w/o Handles
8.1cm (3.2in)
Crawler Width
28.2cm (11.1in)
Crawler Depth
22.6cm (9in)
Right Drive Module Weight
4.2kg (9.3lb)
Right Drive Module Height
12.5cm (4.9in)
Right Drive Module Height w/o Handles
8.1cm (3.2in)
Right Drive Module Width
13.4cm (5.3in)
Right Drive Module Depth
22.6cm (9in)
Circumferential Pipe Range
7cm (2.75in) OD to flat
Longitudinal Pipe Range
30.5cm (12in) OD to flat
Internal, Circumferential Pipe Range
61cm (24in) to OD
Nozzle Size Range
7cm (2.75in)
Radial Clearance w/o Handles
7cm (2.75in) pipes under 20cm (8in), 8.15cm (3.2in) pipes over 20cm (8in)
Vertical Nozzle Clearance
23cm (9in)
Idler Encoder (Right Module)
13.78 counts/mm (22162.8 counts/in)
Motor Encoder (Left Module)
872.5 counts/mm (22162.8 counts/in)
Y-Axis Encoder (Nozzle Application)
161.3 counts/mm (4096 counts/in)
Skew Axis Encoder (Nozzle Application)
2.84 counts/degrees
Driving Speed
Variable 0-25cm/sec (0-10in/sec)
Crawler’s Vertical Payload
10kg (22lb)
Power Requirements
100-240VAC, 50/60Hz, 3.5 Amps
Inspection Surface
Ferrous
Maximum Backpack Payload
1.36kg (3lb)
CE
European Union CE Declaration – Compliance with essential requirements and provisions of European Union directives
FCC
Compliance with Part 15 of FCC rules
Industry Canada
CAN ICES-3 (A)/NMB-3(A) – This class A digital apparatus complies with Canadian ICES-003
Operating Environment
-20°C (-4°F) to 50°C (122°F)
Max. Inspection Surface Temperature
150°C (302°F)
Medium temperature add-on kit required
between 50°C (122°F) and 150°C (302°F)
Environmental Sealing
Dust-tight, watertight

NON-FERROUS INSPECTION SOLUTION

Crawler Weight
4.6kg (10.2lb)
Crawler Height
14.7cm (5.8in)
Crawler Width
20.6cm (8.1in)
Crawler Depth
26.2cm (10.3in)
Circumferential Pipe Range — With Standard Overtop Link
15.2cm (6in) to 106.7cm (42in)
Circumferential Pipe Range — With Large Overtop Link
20.3cm (8in) to 106.7cm (42in)
Encoder Resolution
220.4 counts/mm (5598.4 counts/in)
Maximum Payload
9kg (20lb)
Maximum Speed
Variable 0-14.2cm/sec (0-5.6in/sec)
Power Requirements
100-240VAC, 50/60Hz, 1.4 Amps
Maximum Umbilical Length
30m (98.4ft)
Inspection Surface
Non-Ferrous and Ferrous
Operating Environment
-20°C (-4°F) to 50°C (122°F)
Environmental Sealing
Dust-tight, watertight
Regulations
CE compliance; FCC compliance; Industry Canada compliance; UKCA compliance

ATTACHMENTS — GENERAL

Raster Arm Module Encoder
240.2 counts/mm (6101 counts/in)
Raster Arm Module Speed
0 - 76.2 cm/sec (0 - 30 in/sec)

ATTACHMENTS — STROKE

300mm Raster Arm
300mm (11.8in)
600mm Raster Arm
600mm (23.6in)
900mm Raster Arm
900mm (35.4 in)
11600mm Raster Arm
11600mm (45.7in)

ATTACHMENTS — WEIGHT

300mm Raster Arm (12in)
2.4kg (5.3lb)
600mm Raster Arm (24in)
3.33kg (7.2lb)
900mm Raster Arm (35in)
4kg (8.7lb)
1160mm Raster Arm (45in)
4.6kg (10.2lb)
Standard equipment
  • Standard tool post arms accommodating wedge widths from 17.1mm (0.7in) to 57.6mm (2.3in)
  • Batteries included with the ferrous weld inspection crawlers
Options & accessories
  • Single Crystal Ultrasonic Testing (SCUT) probe kit
  • Twin-crystal UT options
  • Multiple probe kits and corrosion probe holders
  • Umbilical length options up to 60m
  • Interchangeable bridges and raster arm lengths
  • HD cameras
  • Weld Tracking Optical Laser Guides
  • Alternative weld frames, tool posts and tool post arms
  • Actuated tool posts
  • Tracker for automatic weld-profile following
  • Motorized raster arm
  • Backpack for crawler-mounted peripherals
  • Pre-amp bracket
  • Motorized couplant pump
  • Optical guide
  • Camera mount
  • Automated crawler medium temperature add-on kit
  • Large overtop link
  • Remote login options for setup, data capture and analysis
  • User-defined digital output options
Documented compatibility
  • Gekko
  • Mantis
  • TOPAZ
  • Aqualock waterbox
  • 7.5MHz 64-element probe
  • Single Crystal Ultrasonic Testing (SCUT) probe kit
Operating conditions & limits
  • Both crawler configurations have an operating environment of -20°C (-4°F) to 50°C (122°F) and are not submersible.
  • Ferrous crawler performance varies with surface type; heavy payloads may require reduced speeds.
  • The ferrous crawler requires the medium temperature add-on kit when the inspection surface is between 50°C (122°F) and 150°C (302°F).
  • Non-ferrous crawler performance varies with surface condition; umbilical and attachments count toward its 9kg (20lb) payload.
  • The non-ferrous solution specifies a maximum umbilical length of 30m (98.4ft), separately from the general mapping options of up to 60m.
  • Standard weld tool post arms accept wedge widths from 17.1mm (0.7in) to 57.6mm (2.3in).
  • Ferrous solution circumferential pipe range is 7cm (2.75in) OD to flat; longitudinal pipe range is 30.5cm (12in) OD to flat.
  • Non-ferrous solution circumferential pipe range is 15.2cm (6in) to 106.7cm (42in) with the standard overtop link, or 20.3cm (8in) to 106.7cm (42in) with the large overtop link.

Compatibility lists only items named by Eddyfi for this product; confirm configuration with EMUS before ordering.

Applications

Typical applications

  • PAUT and conventional UT corrosion mapping
  • One-axis corrosion surveys
  • High Temperature Hydrogen Attack detection
  • Wet hydrogen sulfide damage assessment
  • Boiler tube and small-diameter pipe weld inspection
  • Austenitic stainless steel weld inspection
  • Carbon steel plate and pipe weld inspection
  • Circumferential, longitudinal and spiral weld inspection
  • Train axle inspection
  • Pressure vessel and pipeline inspection
  • Storage tank shell, roof and sphere inspection
  • Ship hull and marine infrastructure inspection
  • Non-intrusive inspection of ferrous and non-ferrous assets
  • General corrosion, erosion and Microbial Induced Corrosion detection
  • Hydrogen Induced Cracking detection
  • Lamination and inclusion detection
Industries

Sectors served

Gallery

Product imagery

AUT Scanners image 1
AUT Scanners image 2
AUT Scanners image 3
AUT Scanners image 4
AUT Scanners image 5
AUT Scanners image 6
Videos

Product videos

Brochures

Official brochures

Corrosion Mapping Applications Brochure

High Temperature Hydrogen Attack (HTHA) Applications Brochure

Advanced Weld Inspection for Austenitic Steel Applications Brochure

Advanced Weld Inspection for Carbon Steel Applications Brochure

Wet Hydrogen Sulfide Damage Applications Brochure

Train Axle Inspection Applications Brochure

Downloads

Additional documents

Motix Technical Specifications

Motix Technical Specifications

Nav2 Technical Specifications

Nav2 Technical Specifications
Manufacturer

Eddyfi Technologies

Part of the Eddyfi Technologies portfolio, represented by EMUS across the Balkan region.

Knowledge Center

Application Notes & resources

Official application notes and technical literature for AUT Scanners.

Official Application Note pending upload

Request an Engineering Consultation

Talk to an EMUS engineer about this product and whether it fits your inspection workflow.