EMUS — engineering quality control
Eddyfi Technologies|Tubing probes

RFT Single-Driver Boiler Probes

Flexible single-driver RFT probes inspect ferrous boiler tubes, combining spring-loaded centering with waterproof construction for tight bends and submerged operation.

RFT
Overview

Product overview

RFT Single-Driver Boiler Probes use remote-field testing to inspect ferrous tubing. The page identifies RFT as a method for detecting and sizing typical tube defects, including steam erosion, corrosion, baffle cuts and pitting, as well as detecting flaws hidden by support plates.

These probes combine a flexible construction with spring-loaded centering devices to maintain signal quality through the tight bends encountered in boilers. They are designed to pass elbow-shaped bends with a bend radius of 3 X the tube OD, and incorporate a highly kink-resistant cable.

Waterproof construction permits submerged operation, while an onboard preamplifier and a 19-pin Amphenol connector complete the probe configuration. Boiler tubing is the primary application; the page also describes broader RFT uses for wall-loss measurement and flaw detection in feedwater heaters, heat exchangers and piping.

Key Features

Key capabilities

Spring-loaded centering

Spring-loaded centering devices help maintain signal quality while the probe flexes through boiler tube bends.

Bend passage

The probes are designed to pass elbow-shaped bends of 3 X the tube OD bend radius.

Waterproof construction

Waterproof probes support submerged operation.

Onboard preamplifier

An onboard 30 dB preamplifier is incorporated into the probe.

Kink-resistant cable

The cable is highly resistant to kinking.

Amphenol connector

The probes use a 19-pin Amphenol connector.

Wear resistance

The probes are described as very resistant to wear.

Specifications

Published technical specifications

Values as published by Eddyfi Technologies. Where models or variants differ, each is listed separately.

RFT Single-Driver Boiler Probes

Elbow bend passage
3 X the tube OD bend radius
Onboard preamplifier
30 dB
Connector
19-pin Amphenol connector
Standard equipment
  • Spring-loaded centering devices
  • Onboard 30 dB preamplifier
  • Highly kink-resistant cable
  • 19-pin Amphenol connector
Operating conditions & limits
  • The stated RFT inspection applications concern ferrous tubes.
  • Designed to pass elbow-shaped bends of 3 X the tube OD bend radius.
Applications

Typical applications

  • Ferrous boiler tube inspection
  • Submerged tube inspection
  • Wall-loss measurement
  • Pitting detection and sizing
  • Steam erosion, corrosion and baffle-cut detection
  • Detection of flaws hidden by support plates
  • RFT inspection of feedwater heaters, heat exchangers and piping
Industries

Sectors served

Brochures

Official brochures

Tubing Probe Catalog

Downloads

Additional documents

Manufacturer

Eddyfi Technologies

Part of the Eddyfi Technologies portfolio, represented by EMUS across the Balkan region.

Knowledge Center

Application Notes & resources

Official application notes and technical literature for RFT Single-Driver Boiler Probes.

Official Application Note pending upload

Request an Engineering Consultation

Talk to an EMUS engineer about this product and whether it fits your inspection workflow.