Splash Zone Pulsed Eddy Current (PEC) Probe

A rugged PEC probe for detecting corrosion around offshore waterlines through insulation or marine growth, without surface preparation.

PEC
Overview

Product overview

The Splash Zone Pulsed Eddy Current (PEC) Probe is designed to detect corrosion immediately above and below the mean water level on offshore structures, including oil and gas platform legs and risers. Inspection requires neither surface preparation nor removal of marine growth.

Using pulsed eddy current inspection, the probe scans through insulation or marine growth up to 203 mm (8 in) thick and supports metal thicknesses up to 76 mm (3 in). This allows corrosion inspection with the covering material left in place.

A rugged casing and a 25 m (82 ft) heavy-duty cable support offshore inspection work. The probe is watertight down to 15 m (49 ft) in grid-mapping mode, while direct-contact operation is limited to a maximum surface temperature of 70°C (158°F).

Key Features

Key capabilities

Inspection through marine growth

Scans through insulation and marine growth up to 203 mm (8 in) without removing the growth.

Thick-wall capability

Supports inspection of metal thicknesses up to 76 mm (3 in).

Submerged grid mapping

Provides watertightness down to 15 m (49 ft) in grid-mapping mode.

Rugged construction

A rugged casing is designed for offshore applications.

Heavy-duty cable

The probe has a 25 m (82 ft) heavy-duty cable.

No surface preparation

Detects corrosion in the splash zone without surface preparation.

Specifications

Published technical specifications

Values as published by Eddyfi Technologies. Where models or variants differ, each is listed separately.

GENERAL

Casing
Medium
Wall thickness
Up to 76 mm (3 in)
Insulation/coating thickness (liftoff)
0–203 mm (0–8 in)
Footprint at zero liftoff
62 mm (2.4 in)
Encoder
None (add-on only)
Watertightness
15 m (49 ft)
Cable
25 m (82 ft)
Maximum surface temperature
Direct contact operation: 70°C (158°F)
Options & accessories
  • Add-on encoder
Operating conditions & limits
  • Metal wall thickness up to 76 mm (3 in).
  • Insulation/coating liftoff range: 0–203 mm (0–8 in).
  • Watertightness to 15 m (49 ft) applies in grid-mapping mode.
  • Maximum surface temperature for direct-contact operation: 70°C (158°F).
  • No encoder; encoder is add-on only.
Applications

Typical applications

  • Offshore splash-zone corrosion detection
  • Oil and gas platform leg inspection
  • Offshore riser inspection
  • Inspection through insulation and marine growth
  • Submerged grid mapping
Industries

Sectors served

Videos

Product videos

Brochures

Official brochures

Downloads

Additional documents

Lyft Technical Specifications

Lyft Technical Specifications
Manufacturer

Eddyfi Technologies

Part of the Eddyfi Technologies portfolio, represented by EMUS across the Balkan region.

Knowledge Center

Application Notes & resources

Official application notes and technical literature for Splash Zone Pulsed Eddy Current (PEC) Probe.

Official Application Note pending upload

Request an Engineering Consultation

Talk to an EMUS engineer about this product and whether it fits your inspection workflow.