EMUS — engineering quality control
Eddyfi Technologies|Pulsed eddy current probes

Pulsed Eddy Current Array (PECA) High-Resolution Probe

A high-resolution pulsed eddy current array probe for estimating remaining wall thickness through corrosion scabs and blisters without surface preparation.

PECPECA
Pulsed Eddy Current Array (PECA) High-Resolution Probe product image
Overview

Product overview

The PECA-HR probe is designed to estimate remaining wall thickness beneath surface-forming corrosion scabs and blisters. Its dedicated scab inspection solution combines a high-resolution sensor, scanning accessory and processing algorithm, allowing assessment while the asset remains in service without removing corrosion layers or preparing the surface.

An array of dual-coil sensors supports spatial triangulation using pulsed eddy current technology. High-resolution acquisitions and real-time processing with a dedicated scab mode produce C-scan data, while a semi-rigid scab mat maintains constant liftoff during acquisition. Defect detection depends on working within the supported wall-thickness and liftoff ranges.

Operators can use grid acquisition or encoded dynamic scanning, with 75 mm (3 in) coverage per pass. The page states that typical corrosion scabs can be inspected in less than one minute. The solution supports metal thicknesses of 3–19 mm and liftoff of 0–50 mm, providing radiation-free assessment of the remaining ligament.

Key Features

Key capabilities

Dual-sensor array

Three dual sensors provide six channels and support spatial triangulation.

High-resolution acquisition

The specialized dual-coil sensor design supports high-resolution pulsed eddy current acquisitions.

Single-pass coverage

The array covers 75 mm (3 in) in a single pass.

Two acquisition modes

Grid acquisition and encoded dynamic scanning accommodate different inspection workflows.

Dedicated scab processing

Advanced real-time processing and a dedicated scab mode support corrosion-scab assessment and C-scan generation.

Constant-liftoff mat

A semi-rigid scab mat maintains constant liftoff during acquisition.

In-service assessment

Remaining ligament assessment requires no surface preparation and can be performed while the asset stays in service.

Radiation-free inspection

The technique provides 100% coverage without using radiation.

Specifications

Published technical specifications

Values as published by Eddyfi Technologies. Where models or variants differ, each is listed separately.

GENERAL

Casing
Small
Number of channels
6 (3 × patent pending dual sensors)
Total coverage
75 mm (3 in)
Wall thickness
3–19 mm (0.12–0.75 in)
Insulation/coating thickness (liftoff)
0–50 mm (0–2 in)
Weather jacket thickness
Not supported
Outer diameter range
152 mm (6-in) to flat surfaces
Encoder
16.04 counts/mm (407.44 counts/in)
Cable
5 m (16.4 ft)

Inspection performance

Typical corrosion scab inspection time with encoded dynamic scanning
less than one minute
Technique coverage
100%
Options & accessories
  • Semi-rigid scab mat scanning accessory
Operating conditions & limits
  • Supported wall thickness: 3–19 mm (0.12–0.75 in).
  • Supported insulation/coating thickness (liftoff): 0–50 mm (0–2 in).
  • Weather jackets are not supported.
  • Outer diameter range: 152 mm (6-in) to flat surfaces.
  • Defect detection requires operation within the adequate wall-thickness and liftoff range.
  • The less-than-one-minute inspection claim applies to typical corrosion scabs with encoded dynamic scanning.
Applications

Typical applications

  • Remaining wall-thickness assessment through corrosion scabs
  • Corrosion blister inspection
  • In-service remaining ligament assessment
Industries

Sectors served

Videos

Product videos

Brochures

Official brochures

Downloads

Additional documents

PECA HR Technical Specifications

PECA HR Technical Specifications

Lyft Technical Specifications

Lyft Technical Specifications
Manufacturer

Eddyfi Technologies

Part of the Eddyfi Technologies portfolio, represented by EMUS across the Balkan region.

Knowledge Center

Application Notes & resources

Official application notes and technical literature for Pulsed Eddy Current Array (PECA) High-Resolution Probe.

Official Application Note pending upload

Request an Engineering Consultation

Talk to an EMUS engineer about this product and whether it fits your inspection workflow.